Difference between revisions of "Power"

From Fixme.ch
Jump to: navigation, search
Line 16: Line 16:
 
* https://www.flukso.net/files/flm02/manual.pdf
 
* https://www.flukso.net/files/flm02/manual.pdf
 
* https://github.com/flukso/flm02/wiki
 
* https://github.com/flukso/flm02/wiki
 +
 +
Configuration/Dépannage:
 +
Le Flukso est raccordé sur le réseau sur le subnet 130 par son port Ethernet.
 +
Il obtient son adresse par DHCP (Best effort ou pseudo-static 192.168.130.129).
 +
Pour se connecter passer par l'API suivante : http://192.168.130.129
 +
Une fois connecté vous devriez avoir la configuration représentée sur ces images :
 +
[[Image:Status_1.png]]
 +
[[File:Sensor 1.png]]
 +
[[File:Sensor 2.png]]
 +
[[File:Sensor3.png]]
 +
Sinon, reconfigurer le Flukso avec ces paramètres.
  
 
Info
 
Info

Revision as of 16:29, 23 September 2021

  ------------------------------------------
  Chuck Norris doesn't need a smart meter.
  He just grabs the mains every hour to get
  a feel for his electricity consumption.
  ------------------------------------------

FIXME local power consumption monitoring

Doc:

Configuration/Dépannage: Le Flukso est raccordé sur le réseau sur le subnet 130 par son port Ethernet. Il obtient son adresse par DHCP (Best effort ou pseudo-static 192.168.130.129). Pour se connecter passer par l'API suivante : http://192.168.130.129 Une fois connecté vous devriez avoir la configuration représentée sur ces images : File:Status 1.png File:Sensor 1.png File:Sensor 2.png File:Sensor3.png Sinon, reconfigurer le Flukso avec ces paramètres.

Info

Breakers:

  • Q17: lumières
  • Q21: nord
  • Q13: le reste

Sensors

  • L1: 34cde81adabfb1ce819eca8fea6949b6
  • L2: b7755b5f3ec05fcdc67f449241a9912a
  • L3: e67e0685f747b30d855108ab781abdfc

Example

francois@stup:~$ curl 'http://62.220.135.196:8080/sensor/e67e0685f747b30d855108ab781abdfc?version=1.0&interval=minute&unit=watt'; echo
[[1479941621,202],[1479941622,203],[1479941623,201],[1479941624,200],[1479941625,201],[1479941626,202],[1479941627,202],[1479941628,202],[1479941629,202],[1479941630,203],[1479941631,203],[1479941632,203],[1479941633,201],[1479941634,203],[1479941635,201],[1479941636,204],[1479941637,204],[1479941638,204],[1479941639,204],[1479941640,204],[1479941641,204],[1479941642,203],[1479941643,203],[1479941644,203],[1479941645,204],[1479941646,202],[1479941647,202],[1479941648,202],[1479941649,202],[1479941650,203],[1479941651,203],[1479941652,204],[1479941653,205],[1479941654,204],[1479941655,205],[1479941656,204],[1479941657,204],[1479941658,204],[1479941659,204],[1479941660,202],[1479941661,199],[1479941662,201],[1479941663,203],[1479941664,202],[1479941665,204],[1479941666,202],[1479941667,202],[1479941668,201],[1479941669,202],[1479941670,203],[1479941671,204],[1479941672,204],[1479941673,205],[1479941674,204],[1479941675,204],[1479941676,204],[1479941677,203],[1479941678,203],[1479941679,201],[1479941680,"nan"]]
francois@stup:~$ 

How to display current power consumption?

conso.sh:

#!/bin/bash

L1=$(curl -s "http://62.220.135.196:8080/sensor/34cde81adabfb1ce819eca8fea6949b6?version=1.0&interval=minute&unit=watt" | jq .[-2][1])
L2=$(curl -s "http://62.220.135.196:8080/sensor/b7755b5f3ec05fcdc67f449241a9912a?version=1.0&interval=minute&unit=watt" | jq .[-2][1])
L3=$(curl -s "http://62.220.135.196:8080/sensor/e67e0685f747b30d855108ab781abdfc?version=1.0&interval=minute&unit=watt" | jq .[-2][1])

TOTAL=$[$L1+$L2+L3]

echo "$TOTAL W (L1: $L1, L2: $L2, L3: $L3)"

Logging

See https://git.fixme.ch/francois/power.git for implementation, running on Kubernetes on MetaFoo. Which is also sent on InfluxDB and graphed on Grafana: https://power.fixme.ch/dashboard/db/power-consumption?orgId=1

Power consumption of some devices

Power consumption
Device Power Constant [W] Power Peak [W] Phase
Video Projector 200 L2
Foo 63 L3
Metafoo 200 L3
2 Switch Dell 5224 96 L3
Big Fridge 45 380 L2
LEDs (Bright) 451 L1
LEDs (ON, Purple) 202 L1
Old fluorescent tubes 508 L1
TRON 80 L2
Printer 1300 L3
Mac Fablab 90 L2
Laser 100% 420 L2
Extracteur Fumée 400 L3

Electrical Setup

IMG 20180514 185845.jpg IMG 20180514 220321.jpg IMG 20180514 220330.jpg IMG 20180514 220347.jpg Flukso FLS01-currentClamp 20200115.jpg